FLEX-I-LINER® Sealless Self-Priming Rotary Peristaltic Pumps
FLEX-I-LINER® Rotary Peristaltic Pumps
Vanton FLEX-I-LINER® peristaltic type rotary pumps transfer, sample or meter acids, caustics, solvents, salts, chlorides and reagent grade chemicals - even viscous fluids and slurries containing soft solids and abrasives.
Only two non-metallic parts contact fluid - the rugged thermoplastic body block and durable, replaceable elastomeric flexible liner. This easy-to-service construction keeps maintenance and downtime low.
Only two non-metallic parts contact fluid - the rugged thermoplastic body block and durable, replaceable elastomeric flexible liner. This easy-to-service construction keeps maintenance and downtime low.
Unit of Measure
| Items |
/Asset/FlexILiner_lg.png 1058 FLEX-I-LINER® 2 Size Seal-Less Self-Priming Compact Rotary Peristaltic Pump |
/Asset/FlexILiner_lg.png 1059 FLEX-I-LINER® 6 Size Seal-Less Self-Priming Compact Rotary Peristaltic Pump |
/Asset/FlexILiner_lg.png 1060 FLEX-I-LINER® 12 Size Seal-Less Self-Priming Compact Rotary Peristaltic Pump |
/Asset/FlexILiner_lg.png 1061 FLEX-I-LINER® 18 Size Seal-Less Self-Priming Compact Rotary Peristaltic Pump |
/Asset/FlexILiner_lg.png 1062 FLEX-I-LINER® 30 Size Seal-Less Self-Priming Compact Rotary Peristaltic Pump |
|||||
| Description |
N/A
Vanton FLEX-I-LINER® peristaltic type rotary pumps transfer, sample or meter acids, caustics, solvents, salts, chlorides and reagent grade chemicals - even viscous fluids and slurries containing soft solids and abrasives. Only two non-metallic parts contact fluid - the rugged thermoplastic body block and durable, replaceable elastomeric flexible liner. This easy-to-service construction keeps maintenance and downtime low. |
|||||||||
| Brands | N/A FLEX-I-LINER® Vanton | |||||||||
| Flow Rate | N/A 0.33 to 40 gpm0.07 to 9 m³/h | |||||||||
| Temperature Range | N/A Up to 250 ºFUp to 121 ºC | |||||||||
| Size | N/A 2 | N/A 6 | N/A 12 | N/A 18 | N/A 30 | |||||
| Water (H2O) Capacity at 70 ºC and 0 PSI | N/A 0.33 gpm | N/A 1 gpm | N/A 2 gpm | N/A 3 gpm | N/A 5 gpm | |||||
| Intermittent Operating Pressure Range | N/A 0 to 25 psig | N/A 0 to 25 psig | N/A 0 to 35 psig | N/A 0 to 40 psig | N/A 0 to 45 psig | |||||
| Continuous Operating Pressure Range | N/A 0 to 25 psig | N/A 0 to 25 psig | N/A 0 to 30 psig | N/A 0 to 30 psig | N/A 0 to 30 psig | |||||
| Power | N/A 0.25 hp | |||||||||
| Speed | N/A 1750 rpm | |||||||||
| Hose Connection Outside Diameter (OD) | N/A 0.75 in | N/A 0.75 in | N/A 0.75 in | N/A 0.75 in | N/A 1 in | |||||
| Features |
N/A
|
|||||||||
| Additional Information |
N/A
The gentle peristaltic pumping action minimizes foaming, prevents settling out of suspensions and permits safe handling of latex emulsions and other shear-sensitive liquids. Sealless, non-metallic and self-priming, FLEX-I-LINER® pumps operate in either direction, wet or dry, in any position. Their unique design eliminates shaft seals, glands, internal seals, stuffing boxes and other potential sources of leakage. Offered in Pedestal Mount and Close Coupled models, FLEX-I-LINER® pumps can be furnished with electric motors, with rotary vane air motors or with variable speed drives for metering purposes. Every Vanton pump is fully tested to verify performance with all data permanently recorded. Over 140,000 of these dependable sealless, self-priming pumps are in service handling aggressive and other problem fluids. Pumping is accomplished by a rotor mounted on an eccentric shaft rotating within a flexible elastomeric liner. This creates a squeegee action on the fluid, which is trapped between the outer surface of the liner and the inner wall of the body block. Only the rigid thermoplastic body block and the flexible elastomeric liner contact the fluid being pumped. Body blocks are available in polypropylene, UHMW polyethylene and PTFE. Flexible liners can be furnished in natural rubber, Neoprene®, Buna-N®, Hypalon®, Fluorocarbon (FKM), Nordel®. Vanton offers two configurations of FLEX-I-LINER® peristaltic pumps: Pedestal Mount model XB (left) and Close Coupled model CC (right). Interchangeable body blocks and elastomeric liners allow rapid maintenance, minimizing downtime. |
|||||||||
| Design/Construction |
N/A
A rotor mounted on an eccentric shaft oscillates within the flexible liner, imparting a progressive squeegee action on the fluid trapped in the channel between the liner and the body block. Flanges on the flexible liner are pressed to the side of the body block by concentric grooves on the pedestal assembly and the cover plate. This serves to isolate the fluid to the channel. Pump models are available close-coupled or pedestal-mounted to an electric motor, or air-powered for handling volatile fluids. These pumps are ideally suited for use on a variety of stationary and mobile acid buggies for the transfer of chemicals in laboratory and plant operations as well as for incorporation on OEM equipment. FLEX-I-LINER® pumps are also available in duplex configurations with manifolds providing common suction and discharge connections, and in sanitary designs with flame-polished interiors and quick-disconnect fittings. The wide choice of thermoplastics and elastomers in which these pumps are furnished permits their use over the full pH range and for an endless list of corrosive and abrasive clear and viscous fluids. (See Chemical/Material Resistance Chart) |
|||||||||
| Typical Applications |
N/A
XB & CC models satisfy laboratory, production and OEM applications FLEX-I-LINER® pumps are available close-coupled to an electric motor, or pedestal-mounted with electric motor drive or gasoline engine, as well as air powered when required for handling volatile fluids. For metering and dosing, variable speed motors or belt drives may be used. Models may be hand carried, installed on casters, or wheel-mounted on mobile equipment for portability. Sanitary, sealless, metering pump has flame polished body With no internal crevices, dead spots, threads, seals, or bearings, this FLEX-I-LINER® self-priming pump is ideal for sanitary metering of pharmaceuticals, foods, and other contamination-sensitive products. The body block in the unit illustrated is molded of UHMW polyethylene with flame polished interior surfaces, and spin-welded suction and discharge quick-disconnect fittings. The rugged flexible liner is molded of food grade elastomers. Metal never touches fluid. Air-driven plastic pump handles volatile fluids, gases For pumping volatile chemicals and gases where safety requirements prohibit the use of electric power, or in remote areas where electric power is not available, FLEX-I-LINER® pumps can be supplied with rotary vane air motors, which develop 2000 rpm on 90 psi (620 kPa). These motors can be furnished in models for clockwise rotation, or reversible operation to change flow direction. Control of the air motor drive offers a convenient means for varying flow rates. Dosing is automatic, reliable with variable speed pump Variable speed FLEX-I-LINER® pumps offer automatic dosing capability with dependable accuracy. A sensor immersed in the fluid being treated continuously relays data on pH, conductivity, or other variables, to a controller which adjusts pump motor speed and dosage rate. The design simplicity reduces the cost, maintenance, downtime, and complexity associated with dosing and metering applications. Drum pump runs dry, self-primes, cuts maintenance Ideally suited to evacuate drums, the FLEX-I-LINER® pump is self-priming, can run dry for extended periods, and is simple to maintain. It also runs slowly - 1750 versus 5000 rpm for typical drum pumps - and offers greater safety and convenience in a diversity of situations. Compact in size with integral handle, it fits neatly on drum lids without hazardous protrusions, and has sufficient lift characteristics to operate from the floor, skid or stand. Duplex configuration features high capacity, smooth operation Duplex FLEX-I-LINER® pumps offer 70 percent higher flows than "Simplex" configurations while minimizing vibration at higher pressures. One motor/gearbox drives two opposing eccentric shafts oriented 180? out of phase/rotation, canceling pumping pulsations generated within each fluid cavity. Manifolds provide common suction and discharge connections. Duplex systems are available in the same thermoplastic and elastomeric materials as single-stage units. |
|||||||||
| Note | N/A FLEX-I-LINER® peristaltic pumps are available with standard or variable- speed electric motors, air motor drives, or pulley-driven configurations. | |||||||||
|
|
||||||||||